Skip to content

Averaged series

An air-quality standard does not speak of instants: it speaks of averages — one hour, eight moving hours — because that is how air is measured and regulated. The demo’s forecast, by contrast, has a value every 15 minutes. Averaged series are the bridge between the two.

For every species with an entry in the demo’s standard, the platform builds, when the forecast is published:

  • The hourly average, clock-aligned — one figure per hour, at the top of the hour.
  • The 8-hour moving average — at each step, the mean of the preceding eight hours.

No 24-hour average is computed, even for particulate matter, whose standard is written that way. A 24-hour mean of a forecast averages hours that have not happened yet, flattens the very peak an operator decides against, and is only complete once the day is over — by which time it is no longer a forecast. It is the right statistic looking back over hours that did happen, which is a consulting question rather than a forecasting one.

All are computed for the receptors and for the whole grid, in every scenario. From them, also at publication, come each species’ margin — the averaged maximum against the standard’s value, as a percentage — and the grid point where that maximum occurs.

The annual and percentile forms some standards use are not computed; the evaluation is limited to what the registered standards require today.

The map and the markers are instantaneous: the value of the step shown, and the alert levels compared step by step — the demo’s own thresholds, chosen so the forecast reads. The averages are where the standard is read:

  • The Regulatory panel (hidden for now; the rail carries no button for it) puts the receptor’s instantaneous value, its current hour’s mean and the norm on three lines, with the margin as a percentage of the norm. It is an hourly reading: a species whose norm is a 24-hour mean reads as not applicable there.
  • The Series panel’s builder offers each curve as the instant value, the 1-hour mean, the 8-hour moving mean, and draws the norm as a line where the standard has one for that species in one of those forms.
  • The Controls panel can step the forecast by the hour instead of by 15 minutes, so the regulatory reading is walked the way the standard is written.
  • An Alerts row that comes from the standard is tagged Regulatory.

The two readings can disagree on purpose: a receptor can show an alert on an instant and sit well inside the norm over the hour, or the reverse. Both are true; they answer different questions.

→ Air-quality standards · Units and species

Map data © OpenStreetMap contributors · © OpenMapTiles · © MapTiler · Positron design © CARTO · Esri · Copernicus DEM — Data sources and attribution